







Highlights
View Details- Maintain productivity when the power goes out.
- Provides surge, lightning and circuit-overload protection for attached devices.
- Supplies battery power as soon as electrical service is interrupted.
Bn650M1 Back-Ups 650 Va Battery Backup System, 7 Outlets, 650 Va, 490 J
Log in to see pricing



Maintain productivity when the power goes out. All seven outlets provide surge, lightning and circuit-overload protection for attached devices, in addition to five providing battery-operated backup power as soon as electrical service is interrupted. USB port provides charging convenience. Three wide-spaced outlets permit the use of transformer-based plugs. Audible alarms notify you of changing utility power and UPS conditions. The LED status display indicates On Line, On Battery and Building Wiring Fault conditions.
- Maintain productivity when the power goes out.
- Provides surge, lightning and circuit-overload protection for attached devices.
- Supplies battery power as soon as electrical service is interrupted.
- USB connectivity for maximum flexibility.
- Audible alarms.
- LED status indicators.
- Transformer-block spaced outlets.
- Lead-acid battery.
Manufacturer # | BVN650M1 |
Global Product Type | Backup Systems |
Protection Type | Power |
System VA | 650 VA |
Backup Time at Half Load | 10.3 min @ 180 W |
Automatic Voltage Regulation (AVR) | No |
Multimedia Protection | No |
Battery Recharge Time | 10 h |
Connected Equipment Guarantee/Warranty | $75,000 Equipment Protection Policy |
Backup Time at Full Load | 2.5 min @ 360 W |
Connector/Port/Interface | USB |
Joules Of Surge Protection | 490 J |
Number of Outlets | 7 |
Diagnostics/Alarm/Status Light | Alarm |
Diagnostics/Alarm/Status Light | LED |
React Time | 6 ms |
Cord Length | 5 ft |
Housing Material | Plastic |
Color(s) | Black |
Backup Systems Alarm(s) | Audible |
Emergency Power Off (EPO) | No |
Input Frequency | 50-60 Hz |
Model Name/Number | Back-UPS® BN650M1 |
Number of Outlets/Type | 5 UPS/Surge |
Number of Outlets/Type | 2 Surge Only |
Backup Run Time | 4.3 h |
Product Biodegradability Indicator | N |
Product Biodegradability in Days | 0 |
Product Compostability Indicator | N |
Compliance Standards | CEC |
Compliance Standards | cTUVus |
Compliance Standards | Energy Star Rated |
Compliance Standards | FCC Part 15 Class B |
Compliance Standards | REACH |
Compliance Standards | RoHS |
Pre-Consumer Recycled Content Percent | 0% |
Post-Consumer Recycled Content Percent | 0% |
Total Recycled Content Percent | 0% |
Disclaimer Statement | Run Time based on a load of 10 W. |
Maintain productivity when the power goes out. All seven outlets provide surge, lightning and circuit-overload protection for attached devices, in addition to five providing battery-operated backup power as soon as electrical service is interrupted. USB port provides charging convenience. Three wide-spaced outlets permit the use of transformer-based plugs. Audible alarms notify you of changing utility power and UPS conditions. The LED status display indicates On Line, On Battery and Building Wiring Fault conditions.
- Maintain productivity when the power goes out.
- Provides surge, lightning and circuit-overload protection for attached devices.
- Supplies battery power as soon as electrical service is interrupted.
- USB connectivity for maximum flexibility.
- Audible alarms.
- LED status indicators.
- Transformer-block spaced outlets.
- Lead-acid battery.
Attribute Name | Attribute Value |
---|







