Highlights
View Details- Enclosure power distribution unit offers reliable and cost effective power distribution
- Dimensions: 66.5"(H) x 2.1"(W) x 2.1"(D)
- Receptacles: one NEMA L6-30P input, 20 x IEC 60320 C13 and four IEC 60320 C19 output
Eaton Single-Phase Managed Rack Power Distribution Unit, 24-Outlet, Black (EMA107-10)
Log in to see pricing


Same-day Shipping
This product usually ships and arrives up to 1 - 2 days

The Eaton G3 EMA107-10 single-phase managed ePDU facilitates billing grade accuracy monitoring of input and branch circuits on a local LCD pixel display or over a network connection. The high accuracy meter of this ePDU, is perfect for measuring current, voltage, power and energy for load balancing. It also measures capacity planning, efficiency monitoring and energy usage reporting. This ePDU uses a daisy chain that allows four ePDUs to share the same network connection and IP address. It can operate in high operating temperature environments up to 140 degrees F, and has an input and output voltage rating of 230 VAC and power rating of 5.76 kVA.
- Enclosure power distribution unit offers reliable and cost effective power distribution
- Dimensions: 66.5"(H) x 2.1"(W) x 2.1"(D)
- Receptacles: one NEMA L6-30P input, 20 x IEC 60320 C13 and four IEC 60320 C19 output
- Voltage: 230 VAC input/output at 50/60 Hz, Input current: 24 A, Circuit breakers: (2) 20 A
- Output capacity: 5.76 kW
- Input cord length: 10'
- Form factor: Vertical (0U)
- Has high accuracy meter that measures current, voltage, power and energy for load balancing, capacity planning & energy usage reporting
- High operating temperature (140 deg F/60 deg C) for containment or hot network closet environments
- Outlet switching allows for on/off/reboot of individual outlets reducing the cost of managing remote or local IT data center environments
- IEC outlet grip plug retention secures plugs in place using standard cables
- Has outlet switching for on, off and reboot control to minimize management costs and outlet level metering to +/- 1 percent billing grade accuracy
- Daisy chain of IP addresses enables four devices to share one network connection to minimize up to 75 percent network installation costs
- cUL Certified
Manufacturer # | EMA10710 |
Brand Name | Eaton |
Cable Length (ft.) | 10 |
Depth in Inches | 2.1 |
Height in Inches | 66.5 |
Input Connector | One NEMA L6-30P |
Input Current | 24 A |
Load Capacity | 5.76 kVA |
Operating Temperature (fahrenheit) | Up to 140 deg F |
Outlet Count | 24 |
Output Frequency | 50/60 Hz |
Output Voltage | 230 VAC |
Phase | Single-Phase |
Power Distribution Unit Type | Managed Rack |
True Color | Black |
Width in Inches | 2.1 |
Details
The Eaton G3 EMA107-10 single-phase managed ePDU facilitates billing grade accuracy monitoring of input and branch circuits on a local LCD pixel display or over a network connection. The high accuracy meter of this ePDU, is perfect for measuring current, voltage, power and energy for load balancing. It also measures capacity planning, efficiency monitoring and energy usage reporting. This ePDU uses a daisy chain that allows four ePDUs to share the same network connection and IP address. It can operate in high operating temperature environments up to 140 degrees F, and has an input and output voltage rating of 230 VAC and power rating of 5.76 kVA.
- Enclosure power distribution unit offers reliable and cost effective power distribution
- Dimensions: 66.5"(H) x 2.1"(W) x 2.1"(D)
- Receptacles: one NEMA L6-30P input, 20 x IEC 60320 C13 and four IEC 60320 C19 output
- Voltage: 230 VAC input/output at 50/60 Hz, Input current: 24 A, Circuit breakers: (2) 20 A
- Output capacity: 5.76 kW
- Input cord length: 10'
- Form factor: Vertical (0U)
- Has high accuracy meter that measures current, voltage, power and energy for load balancing, capacity planning & energy usage reporting
- High operating temperature (140 deg F/60 deg C) for containment or hot network closet environments
- Outlet switching allows for on/off/reboot of individual outlets reducing the cost of managing remote or local IT data center environments
- IEC outlet grip plug retention secures plugs in place using standard cables
- Has outlet switching for on, off and reboot control to minimize management costs and outlet level metering to +/- 1 percent billing grade accuracy
- Daisy chain of IP addresses enables four devices to share one network connection to minimize up to 75 percent network installation costs
- cUL Certified
Attribute Name | Attribute Value |
---|